BFX Series

The BFX series fiber optic amplifiers feature dual digital LCD display for displaying present value and set value. The amplifier units feature quick response rates up to 50 ㎲, allowing detection of fast moving targets and high accuracy. The units feature 5 different response speed settings and 4 different sensitivity settings, for flexible application in diverse environment settings.

Description

  • LCD dual display for displaying present value and set value
  • High resolution (1/10,000) for detecting tiny targets
  • Ultra-fast response speed (50 ㎲) for detecting fast moving targets
  • 5 response speeds
    : Ultra-fast mode (50 ㎲), fast mode (150 ㎲), standard mode (500 ㎲), long-distance mode (4 ms), ultra-long-distance mode (10 ms)
  • Saturation prevention function: prevent errors from saturation of received light
  • External input function
    : emitter OFF, remote sensitivity setting, peak value reset, output ON/OFF/MAINTAIN, energy saving mode OFF functions
  • Various sensitivity settings
    : Manual sensitivity setting (fine-adjusting sensitivity)
    : Teaching sensitivity setting (Button/external input – auto-tuning, one-point teaching, two-point teaching, position teaching)
  • Slim and compact design (W 10 x H 30.6 x L 70.5 mm)

Dual Digital Display

With the dual digital display screen, users can easily identify the present value (PV) and set value (SV)Dual Digital Display

High-Speed Response Rate of 50 ㎲ for Detecting Fast Moving Targets

The sensors feature 5 different response speeds: Ultra-fast mode (50 ㎲), fast mode (150 ㎲), standard mode (500 ㎲), long-distance mode (4 ms), ultra-long-distance mode (10 ms). The units can detect fast moving targets in ultra-fast mode (50 ㎲).High-Speed Response Rate of 50 ㎲ for Detecting Fast Moving Targets

Saturation Prevention Function

When detecting transparent objects or if the target moves out of position, the received light intensity may increase. The saturation prevention function prevents errors from light saturation by adjusting to the difference in the received light.Saturation Prevention Function

Simple Sensitivity Adjustment

Simply press the SET key once to activate automatic sensitivity teaching. Teaching sensitivity can be set in auto-tuning, one-point teachingSimple Sensitivity Adjustment

Various Sensitivity Setting Modes

Depending on the environment, users can choose between auto-tuning, one-point teaching (maximum sensitivity), two-point teaching, and position teaching modes.Various Sensitivity Setting Modes

Inverted Display

The display direction can be inverted depending on installation settings for easier status readings.Inverted Display

Title Type Size
BFX Series

Instruction Manual

application/pdf 864 KB
BFX Series

Catalog

application/pdf 1 MB
Fiber Optic Sensors

Technical Description

application/pdf 1 MB
BFX Series (CE Mark)

Certification

application/pdf 2 MB